Cryogenic Liquid Storage Tanks for Reliable Gas Supply

 

 

Our vacuum-insulated cryogenic liquid storage tanks are engineered for safe storage and continuous supply of liquid nitrogen (LIN), liquid oxygen (LOX), liquid argon (LAr), LNG, and liquid CO₂. Designed for industrial gas plants, healthcare facilities, energy projects, and process industries, the tanks are available in vertical and horizontal configurations with customized capacity, pressure ratings, and code compliance.

 

 
  • LO₂ Storage Tank

    A liquid oxygen (LO₂) storage tank is a double-wall, vacuum-insulated pressure vessel engineered for bulk cryogenic oxygen storage. Designed in vertical or horizontal layouts, it acts as a primary...

  • LN Storage Tank

    Vertical liquid nitrogen (LN₂) storage tanks are double-walled, vacuum-insulated cryogenic pressure vessels designed for the storage and supply of liquid nitrogen at −196°C. They provide a...

  • LAR Storage Tank

    Liquid Argon (LAR) storage tanks are double-walled cryogenic pressure vessels designed for the safe storage and supply of liquid argon at -186°C. They are widely used in industrial gas...

  • Flat-bottomed Storage Tank

    Flat-bottomed storage tanks are vertical, cylindrical, atmospheric vessels designed for stationary liquid containment. Featuring a continuous bottom plate for uniform load distribution on concrete...

 
Cryogenic Tank Capacity and Pressure Ratings

 

Parameter

Standard Cryogenic Tanks (LIN / LOX / LAr)

Specialized Cryogenic Tanks (LNG / LCO₂)

Storage Capacity

5–200 m³ standard, customized available

Customized according to project requirements

Design Pressure

0.8 / 1.6 / 2.4 MPa typical options

Determined according to medium properties and operating conditions

Design Temperature

Up to -196°C

According to stored medium and design requirements

Insulation Type

Vacuum multilayer insulation system

Vacuum insulation with medium-specific design considerations

Applicable Codes

ASME VIII Div.1, EN 13458, or project specifications

Applicable pressure vessel and local regulatory requirements

Typical Applications

Industrial gas supply, hospitals, laboratories, manufacturing plants

Energy, LNG stations, CO₂ recovery and process industries

 

Representative Models

 

Static evaporation rates are reference values measured under specified test conditions. Actual performance depends on ambient temperature, operating pressure, filling level, piping configuration, and site conditions.

 

Model

Nominal Capacity

MAWP

Typical Static Evaporation Rate*

Dimensions (Ø × H)

Empty Weight

JLT-10/16

10 m³

1.6 MPa

≤0.40%/day

Approx. Ø2.2 × 6.0 m

Approx. 7.5 t

JLT-30/16

30 m³

1.6 MPa

≤0.30%/day

Approx. Ø3.0 × 8.5 m

Approx. 18 t

JLT-50/08

50 m³

0.8 MPa

≤0.25%/day

Approx. Ø3.4 × 10.5 m

Approx. 26 t

 

Construction

 

 

Inner vessel

Austenitic stainless steel selected for the design temperature, pressure, and stored medium.

 

Outer shell

Carbon steel or other suitable materials selected according to environmental conditions, structural requirements, and project specifications.

 

Piping

Stainless steel piping selected for cryogenic temperatures and thermal movement.

 

 

Vertical vs. Horizontal Cryogenic Tanks
 

Vertical tanks: Reduce ground space requirements but need sufficient overhead clearance for installation.

Horizontal tanks: Suit sites with height restrictions and use saddle supports on engineered foundations.

Selection depends on available installation space, transportation conditions, foundation design, and operating requirements.

 

Valves & Instrumentation

 
 
01
 

Standard Supply Configuration

Liquid filling and discharge connections
Gas-phase balance and pressure-building connections
Pressure relief and vacuum protection devices, as required by the design
Local pressure gauges and differential-pressure liquid level indicators

 
02
 

Optional Equipment

Dual relief valves with a changeover valve, where specified
4–20 mA pressure and level transmitters for remote monitoring
Economizer circuits and external pressure-building vaporizers
Oxygen-service cleaning for LOX applications

 
03
 

Control and Monitoring Options

Remote pressure and liquid level monitoring
High/low pressure alarms
Digital signal output for plant control systems
Customized instrumentation according to customer requirements

LAR Storage Tank

 

 
Installation Requirements

Foundation

Design for the tank's filled operating weight, wind loads, and seismic conditions.

Piping

Provide independent pipe supports and accommodate thermal movement to limit nozzle loads.

Safety

Installation layout shall consider equipment clearance, vent routing, oxygen safety requirements (for LOX service), and applicable local regulations.

Engineering documents

Foundation loads, anchor bolt layouts, and installation instructions support site preparation.

 

Factory Testing

 

Material traceability: Mill test certificates are verified for pressure-retaining parts.

 

Weld inspection: Inner vessel welds undergo radiographic (RT) or ultrasonic (UT) testing in accordance with the design code.


Hydrostatic test: Pressure testing is performed according to the applicable design code, approved inspection plan, and project requirements.

 

Leak and vacuum test: Helium leak testing is performed on the inner vessel and piping, followed by final annular vacuum verification.

 

Final inspection: Instruments, safety devices, and nameplate data are checked, and test records are compiled into the data book.

Flat-bottomed Storage Tank

 

 
 
Design Codes & Compliance
01.

Design codes

ASME Section VIII, Division 1, or EN 13458, as applicable to the project.

02.

Quality management

Manufacturing and inspection processes are managed under the applicable quality system.

03.

Certification

ASME U Stamp or PED conformity assessment may be available subject to the manufacturer's authorization and project requirements.

04.

Third-party inspection

Inspection and test witnessing can be arranged according to the agreed Inspection and Test Plan (ITP).

 

After-Sales Support
 
 

Documentation

GA drawings, P&IDs, foundation load data, and operation and maintenance manuals, as specified in the contract.

 
 
 

Spare parts

Recommended spare parts lists support maintenance planning.

 
 
 

Technical support

Remote engineering assistance, drawing clarification, and commissioning guidance are available according to the agreed service scope.

 

 

modular-1
Request a Cryogenic Tank Quote

For an accurate quotation, please provide:
Stored medium: LOX, LIN, LAr, LNG, LCO₂, or other
Required capacity: 5–200 m³ or custom
Design pressure: Required MAWP or project pressure specification
Configuration: Vertical or horizontal
Codes and certification: Applicable ASME, PED, ISO/GB, or third-party inspection requirements
Destination and site conditions: Country, ambient temperature, wind loads, and seismic requirements

 

 

FAQ

 

Q: What is the typical daily evaporation rate (NER)?

A: Static evaporation rates vary according to tank size, insulation performance, ambient conditions, operating pressure, and filling level. Reference values are provided in the technical datasheet.

Q: What is the service life and maintenance requirement?

A: The expected service life depends on design conditions, operating environment, maintenance practices, and periodic inspections.

Q: Can one tank store LIN, LOX, and LAr?

A: Yes. Tanks can be configured for LIN, LOX, or LAr service when material selection, cleanliness requirements, pressure rating, and safety accessories are confirmed for the intended medium.

Q: How do I size the tank?

A: Size the tank for 7–14 days of average consumption, plus 10–15% ullage and a delivery reserve.

Q: Why does LOX service require special cleaning?

A: Oil, grease, and organic residues can ignite in pure oxygen. Wetted parts must be degreased and verified to standards such as CGA G-4.1.

Q: What is the lead time for a standard tank?

A: Standard models such as JLT-30/16 take 60–90 days from drawing approval. Tanks of 100 m³ and above, or custom-code tanks, take 120–180 days.

Q: What happens if the vacuum degrades?

A: Frost on the outer shell and increased evaporation are common signs. The tank must be emptied and re-evacuated by qualified personnel.

Q: What does the warranty cover?

A: The warranty covers 12 months after commissioning or 18 months after shipment, whichever comes first. It covers manufacturing defects and vacuum loss, but excludes wear parts, improper operation, and non-compliant LOX cleaning.

As one of the most professional cryogenic liquid storage tank manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to buy durable cryogenic liquid storage tank for sale here from our factory. We also accept customized orders.

Send Inquiry