CO₂ Recovery Device for Natural Gas Boiler Exhaust
It is supplied as skid-mounted or modular units for direct integration into new or existing industrial boiler plants.
Introduction
This CO₂ recovery system extracts, separates, and purifies carbon dioxide from post-combustion exhaust produced by natural gas-fired industrial boilers and power generation units.
It is supplied as skid-mounted or modular units for direct integration into new or existing industrial boiler plants.
CO₂ Recovery Performance
CO₂ Capture Rate: 85% to 92% under rated operating conditions.
Inlet Flue Gas CO₂ Concentration Range: 4.0 vol.% to 9.5 vol.% (dry basis).
Recovery Performance Under Turn-Down: Maintains ≥ 80% capture rate between 50% and 110% of rated flue gas flow.
Design Operating Point: Optimized for 8.0 vol.% CO₂ flue gas concentration at 40°C absorber inlet temperature.
Operating Availability: Designed for up to 8,000 operating hours per year, subject to scheduled maintenance and site operating conditions.
Guaranteed Performance Tolerance: ±2 percentage points at the specified design operating point.
Compatibility
Applicable Boiler Types: Fire-tube boilers, water-tube industrial boilers, combined heat and power (CHP) heat recovery steam generators (HRSGs), and thermal oil heaters.
Compatible Boiler Output: 2 MW to 50 MW equivalent thermal input per capture train; larger boiler capacities can be served by multiple parallel trains.
Flue Gas Inlet Temperature Range: 120°C to 220°C (before pretreatment quenching).
Fuel Compatibility: Pipeline natural gas, liquefied natural gas (LNG), and treated coalbed methane (CBM).
CO₂ Product Purity & Output Specifications
|
Parameter |
Industrial Standard Grade |
High-Purity Grade |
|
CO₂ Concentration |
≥ 99.5% |
≥ 99.99% |
|
Oxygen (O₂) |
≤ 0.5 vol.% |
≤ 10 ppm (via catalytic O₂ removal) |
|
Moisture / Dew Point |
Pressure dew point ≤ -40°C |
Moisture ≤ 10 ppm; pressure dew point ≤ -60°C |
|
Carbon Monoxide (CO) |
≤ 20 ppm |
≤ 5 ppm |
|
Total Hydrocarbons (as CH₄) |
≤ 50 ppm |
≤ 20 ppm |
|
Nitrogen & Argon (N₂ + Ar) |
≤ 0.45% |
≤ 100 ppm |
|
Other Trace Impurities |
≤ 0.05% |
≤ 5 ppm |
|
Delivery Pressure |
1.5 MPa to 2.5 MPa (Gas) |
2.0 MPa at -20°C (Liquid) |
CO₂ Capture Process
Primary Separation Technology: Thermally regenerable chemical solvent absorption process optimized for low-partial-pressure post-combustion exhaust.
Overall Process Sequence: Pretreatment → CO₂ Absorption → Solvent Regeneration → CO₂ Compression & Dehydration → Product Gas/Liquid Distribution.
Capture Rate Basis: Calculated from the difference between CO₂ entering and leaving the capture system, based on measured flue gas flow and CO₂ concentration.
Solvent Regeneration Method: Low-pressure steam reboiler supplies heat to strip bound CO₂ at 115°C–122°C.
Energy Consumption & Pressure Drop
Thermal Energy Consumption (Reboiler Duty): 2.8 to 3.4 GJ per tonne of CO₂ recovered (supplied via low-pressure saturated steam at 0.2 MPa–0.3 MPa).
Specific Electrical Energy Consumption: 110 kWh to 160 kWh per tonne of liquid CO₂ (Basis: includes flue gas booster fan, solvent circulating pumps, cooling pumps, CO₂ compression, dehydration, and liquefaction refrigeration).
Flue Gas System Pressure Drop: Total pressure differential across flue gas circuit (pretreatment + absorber) is 2.5 kPa to 4.0 kPa.
Process Makeup Water: 0.1 to 0.3 m³ per tonne of CO₂ (dependent on flue gas inlet temperature and humidity).
Boiler Integration & Retrofit Requirements
Tie-in Point: Exhaust duct connection downstream of boiler economizer/air preheater and upstream of existing stack.
Bypass Damper System: Automated, fast-acting dual-louver bypass damper with mechanical interlock ensures unimpeded boiler exhaust to the stack during CO₂ system startup or trip.
Safe Boiler Bypass: The bypass system maintains the boiler exhaust path independently of the CO₂ recovery unit during startup, shutdown, maintenance, or emergency trip conditions (CO₂ system failure does not cause boiler shutdown).
Booster Blower Integration: Variable Frequency Drive (VFD) controlled booster fan maintains neutral pressure (0 Pa to -50 Pa) at the boiler tie-in point.
FAQ
Q: What warranty and support are provided?
A: The standard warranty is 12 months after commissioning or 18 months after shipment, whichever comes first. Solvent and catalyst are excluded as consumables. Support includes 24/7 remote monitoring and on-site engineers within 7 days when required.
Q: Should I produce gaseous or liquid CO₂?
A: Liquid CO₂ is suitable for storage, transport, beverage production, and food freezing. Gaseous CO₂ at 1.5–2.5 MPa is better suited to nearby pipeline users such as greenhouses.
Q: How much CO₂ can be recovered?
A: A natural-gas boiler produces approximately 0.2 tons of CO₂ per MWh of thermal input. A 10 MW boiler can generate about 48 tons/day and recover approximately 41–44 tons/day at an 85%–92% capture rate.
Q: Can the recovered CO₂ meet beverage-grade requirements?
A: With activated-carbon polishing, CO₂ purity of ≥99.99% can meet applicable ISBT or EIGA beverage requirements.
Q: How much solvent is consumed?
A: Amine solvent consumption is typically 0.3–0.8 kg per ton of CO₂. With reclaimer operation, a full solvent charge generally lasts 2–4 years.
Q: What emissions and waste are generated?
A: With a water-wash section, treated flue gas typically contains less than 5 mg/Nm³ of amine emissions. Reclaimer waste is approximately 0.5–2 kg per ton of CO₂.
Q: How is performance verified?
A: A 72-hour performance guarantee test verifies capture rate, product purity, steam consumption, and power consumption using calibrated meters and CO₂ analyzers. Buyer or third-party witnessing can be arranged.
Hot Tags: co₂ recovery device for natural gas boiler exhaust, China co₂ recovery device for natural gas boiler exhaust manufacturers, suppliers, factory, CO2 capture from flue gas, CO2 recovery flow rate, CO2 recovery technology, combustion gas recovery plant, exhaust gas capture system, flue gas purification system